Sunday, September 9, 2012

Failing an underground Oil Tank Test

#1. Failing an underground Oil Tank Test

Failing an underground Oil Tank Test

Interpretation, next step planning, arresting & retaining the customer

Failing an underground Oil Tank Test

Fuel oil dealers primarily write back to change by reacting to competitive store forces. First it was the Cod discounters, then it was the gas clubs and we reacted to each in kind. Now with the private tank subject looming, dealers are again buffeted by troops that work on our markets. Will we react as before or will we promote programs to derail threats? In New York and New Jersey, The Homeowner's Environmental Loss security program
set a precedent, becoming a needful tool to thwart gas conversions, but more tools are needed, especially to lug the uncontrollable leak of accounts that occur at the time of a
property transaction.

As vice president and founder of Annis Fuel Oil service (Afos), in the early 1980's I recognized private oil tanks as an area of opportunity. With passage of the New Jersey perilous Substance warehouse Act and amendments to the Spill Act, tank work began to overlap with environmental science. Four years of college chemistry paid off. While spinning off Anco Environmental in 1991, I remained loyal to my oil business beginnings. As a small oil dealer I am sensitive to the
threat Ust hysteria poses. With diplomacy I store Ust services to local fuel dealers who otherwise compete with my family's oil company. Instincts say deny or minimize the Ust problem. But the distant environmental storm is looming and must be addressed. Our
customer's financial interests are at stake and they seek leadership. Fuel dealers must address and deflect the social relations damage caused by leaking private tanks, learn how to take an proper tank test, define the true adversary behind the oil tank debacle and finally, find solutions. I hope the material presented herewith will help in these areas, and preclude the loss of oil heat customers to other forms of fuel at the point of real estate transfer. As both of my clubs control primarily in New Jersey, many references are made to New Jersey agency of Environmental security (Njdep) regulations. These regulations may be mirrored by similar regulations in other states. Check your state Environmental security agency for specific regulations governing your area.

Misinformation

The gas clubs have spearheaded marketing campaigns implying that oil heat causes private pollution. Our observations preserve the opposite conclusion. Statistically more remediation projects involve abandoned or improperly complete tanks than active tanks. Homeowner guarnatee policies decline most Ust pollution claims, therefore the leaking tank owner who converted to gas heat finds himself in a greater bind today than he who stayed with oil. But where the gas heated homeowner gets stuck with the remediation bill the oil business shoulders the negative fallout. To win the social relations game, it behooves the fuel business to deflect the problem. Redirect the emphasis from 'oil heat' to 'underground tanks,' and take a proactive stand.

A fuel oil catalogue is most vulnerable at the point of a property transaction. Tank testing and site certification is becoming more commonplace. Driven by liability concerns and the 'due diligence' audit requirement defining the innocent purchaser, buyer's attorneys accumulate their client's the right to test around an oil tank. Due largely to social misconceptions, this mechanism will continue to bash oil heat far into the future.

Know Your Adversary

Recently a fuel dealer told me "...it's the lawyers. They've blown this out of proportion." Others say it's the gas companies, or the gas heating contractors, or the Realtors, or the yank-a-tankers. All these parties are a vocal reaction to the true, silent adversary; corrosion. Low pH soils coupled with a high water table enable a high ion exchange rate with the tank. Non homogenous backfill concentrates the resulting electrochemical reaction at points of greatest electrical conductivity. Therefore, soil particles with conducive mineral article or construction debris that touches the tank completes the corrosion circuit. Over time, this reaction dissolves a hole into the tank. Laws of chemistry and physics are accelerated by poor construction practices. This is the fundamental force behind the tank problem.

If we look at the history of environmental regulations, the foundation was the 1977 Federal Clean Water Act. This legislation focused on industrial polluters. In 1984 with the passage of the New Jersey Environmental Cleanup responsibility Act (Ecra),
regulation-driven liability made the nearnessy of an Ust a sick for industrial property owners. This was the distant thunder of today's Ust debacle. Stricter industrial environmental regulations have trickled down to residential situations.

In June of 1993 Ecra was amended and renamed Isra, industrial Site salvage Act. Many safe bet changes made the regulations more "user friendly", and even kind with the creation of a spill fund. Virtually unnoticed in these amendments, however, was a companion change to the Spill compensation and control Act (Spill Act), introducing a principle significantly affecting all current and time to come owners of real property in New Jersey. The new principle promulgates that time to come owners of polluted property are liable for contamination they did not cause. The potentially devastating language of this amendment makes buyers responsible for any extraction of a perilous substance unless they can satisfy safe bet criteria:
That they acquired the property through an inheritance; That they acquired the property after the extraction occurred; Lack of knowledge at the time of acquisition that any perilous materials had leaked; Lack of involvement in the administration of the leaked perilous substances before acquisition; Notice to the Njdep upon actual discovery of the discharge.

In order to demonstrate that a new owner did not know and had no think to know of the extraction of perilous substances at the property, the acquiring party "must have undertaken, at the time of acquisition, all proper inquiry into the old proprietary and uses of the property." "All proper inquiry" requires the carrying out of a initial assessment, and if necessary, a site investigation. In the case of an private warehouse tank, nothing short of soil testing meets the proper inquiry" threshold, qualifying a damaged buyer as an "innocent purchaser." This understanding is the cornerstone of the "innocent purchaser offense" used by buyers in race of responsible or
contributory negligent parties to the property transaction. Driven by regulation and just old fashion 'let the buyer beware', tank testing is here to stay.

Choosing The Right Tank Test

The proper test is a function of tank status, site conditions and overall objective. Verifiability and timeliness of results are additional test choice criteria. Test limitations, inherent false safe bet and false negative conditions are discussed following the introduction of each technique.

An summary of tank testing methodology is reprinted from Anco's Ust Line*, Issue #4. It poses the question "which tank testing method is best?" The purpose of a tank test is two-fold: to protect the buyer from a past leak and to protect the seller from being blamed for a problem that did not exist when he sold his house. To perform these objectives, we seek one answer: has the tank in question leaked and created an environmental problem? In short, is the site contaminated?

In choosing a test to write back this question, the first concerns will be exact results and verifiability. Ease of scheduling, quick results and cost are prominent as well. Finally, a test is needed that is applicable to the right situation that takes into observation soil stratigraphy and compensates for site conditions.

The best testing choice will meet all or most of the accuracy, verifiability, speed and cost objectives.

There are three major categories of tank tests: liquid, air and soil tests. The first two are in-tank test piquant delicate computer based instrumentation that measures the loss rate of a reagent, liquid or gas, as it leaks out of the tank. This is as a matter of fact the drawback of in-tank tests. Will a buyer find any rate of leaking acceptable? Probably not. But the Njdep does. To help compensate for safe bet limitations of these tests, the Njdep
has instituted a pass/fail leak threshold of .05 gallons per hour, below which the tank will legally "pass" the test. But this "acceptable" leak rate is 1.2 gallons per day, or 438 gallons per year. This will not be proper to most buyers.

For liquid tests, or volumetric tests, the tank must be filled with oil up into the neck of the fill pipe. Miniature volume changes are observed and the tank fails only if the oil level decreases at a rate surpassing .05 gallons per hour.
Benefits: This test entails no exterior disturbance. Drawbacks: False safe bet results, indicating a leak, are not uncommon for conditions as benign as lose threads on the fill pipe. A fuel delivery must be tightly coordinated with the carrying out of the tank test itself. This involves additional expense. Worse still, if the tank does have a leak the test itself will extraction more contamination into the soil. Verifiability: Beyond test data review, verification is impossible without unblemished retesting.
Air Tests come in three types: pressure testing, vacuum testing and tracer testing. Pressure testing involves applying air pressure to the tank and watching for pressure drops. This is an outdated test which can blow out a weak spot in the tank and generate a needful leak.

Vacuum testing involves plugging all pipes to the tank applying a vacuum, then listening through a hydrophone for leak sounds.

Tracer testing involves injecting an isotope of a rare gas into the tank and using sensors placed exterior of the tank to sense a the leak of the rare gas. Results can take up to 10 days to process due to the gas migration period: i.e.: clayey soils decelerate the migration rate.
Benefits: Vacuum and tracer tests are easy to coordinate, involve no exterior disturbance and test the piping as well. Drawbacks: False safe bet results from lose fittings are not uncommon and the volumetric measure of these tests use the .05 gallons/hour standard. Verifiability: Other than data review, verifiability is only inherent through unblemished retesting.

The third category, the soil test, directly measures the whole of oil that has already leaked, answering the central question directly, simply and cost effectively.

In this test, soil samples are retrieved from around the tank at depths of 6"-12" deeper than the bottom of the tank. These samples are tested for petroleum hydrocarbons. Results are immediately available. Some methods comprise hand digging to the top of the tank to check visually for signs of corrosion and to as a matter of fact find the edge of the tank. Clearly, the closer the sample's nearnessy to the tank, the more exact its representation of fundamental soil conditions. Analytic results are checked against Njdep action levels for problem identification.
Benefits: This is a easy test, not relying on electronic instrumentation. It detects oil spills from any source, along with previously removed leaking tanks and overfills. Contamination resulting from overfill is as a matter of fact differentiated from deeper contamination resulting from a tank failure. This method is applicable to any private tank, whether it is active (in use) or out of service. Even previously complete tanks can be tested to resolve whether the tank leaked before closure and if that leak was not remediated. Drawbacks: Soil testing disturbs the soil, as this is an out-of-tank test that seeks the affects of a leak. Verifiability: 1 1/2" diameter bored holes can remain open, facilitating independent sample collection.
The Next Step

After receiving test results, what should be done if there is suspicion of a leak or confirmed contamination? The next step is to resolve if the test results are valid and if the site is contaminated. Vessel tests alone will not tell you this, so a soil test should be performed. Incorporated into this test can be tank and piping inspections to eliminate those conditions prominent to inherent false safe bet results.

Once it is considered the test is valid, it is now time to perform quantitative analysis, describe the extent of contamination and/or plan for the tank extraction and site remediation.

With the quantitative analysis, levels are compared with applicable action levels. Where levels exceed state regulations, a tank extraction is as a matter of fact required. But action levels loose their meaning when the question is asked. Why is there any oil 12" below the tank? It is arguable that small quantities are general however, low levels may be the telltale sign of imminent gross tank failure. Anco recently removed a tank where bored soil sample Total Petroleum Hydrocarbon (Tphc) analytic results were at 150 parts per million. The dealer recommended extraction even though results were well below the first Njdep action level of 1000 ppm. (Njdep allows up to 10,000 ppm Tphc is some cases). This dealer's suggestion rose above an often displayed instinct to deny the problem. Upon extraction the tank was found to have dozens of pin holes in it. In this case, the dealer's concern for his buyer prevented a small problem from becoming a huge problem. Most significantly, it preserved the account.

Planning

All disposal facilities want varied laboratory analyses. proper turn around time for these tests is two to three weeks. This is also the typical lead time in the middle of tank extraction contracting and actual mobilization for removal. The job should be coordinated so the testing is completed before mobilization. Such planning will expedite the clean-up and shorten the project period by about three weeks.

Securing contaminated soil clearance at an stylish disposal installation ahead of time allows the tank removal, soil digout and disposal to be done as one operation. This eliminates the need to return to the site at a later date to take off the contaminated soil. This is needful for fast job completion and during the winter months to preclude the dug out soil from frozen into a solid lump. This particular carrying out coming should be less high-priced than the tank extraction - soil digout - stockpile - then return to loadout alternative.

Therefore, the most direct path towards expeditious site remediation requires soil testing.

Prevention

So far we have covered steps that consequent a failed tank test. Because tank testing is commonly performed by the buyer before a real estate transfer, the oil catalogue is now at risk of being lost. What can be done to preclude an catalogue from being subject to a tank test in the first place?

The first proactive choice is to work with the seller before he lists the property and change the catalogue to gas. This is the poorest choice for our industry. The quick gas conversion sale looses that catalogue forever. Historically, this choice has left our business with a patrimony of improperly complete tanks. These finally come to light and by connection tarnish fuel oil's name. Improperly complete tanks will continue to be a more needful social relations problem than active Ust's as there is no direct financial assistance for private contamination if they leak.

Let's modify the first choice by limiting the offer of gas conversion services. Furthermore, when conclusion out an private tank (in conjunction with the gas conversion), rout out private contamination at that time, by offering only tank removals or soil investigations in conjunction with in-place closures. If a problem is discovered the financial hardship becomes an immediate consequence of the decision to change to gas. This hardship merits less condolence than that endured by the innocent property owner who later discovers an inherited problem. This coming turns the table on gas market's ruthless portrayal of oil heat as a polluter.

My second suggestion is for oil dealers to selectively encourage their customers to move away from old particular walled steel private tanks to basement tanks, above ground tanks, or duplicate walled tanks. This must be done with great delicacy and finesse. It requires readdressing the private tank situation from 'no problem' to 'eventual problem'. It requires action before the tank starts to leak. This minimizes the inherent for cost overruns and wins greatest buyer appreciation.

One coming already being implemented by some fuel oil dealers is a selective tank exchange program. An safe bet limitation includes funding, however, where it is physically inherent to install a 275 gallon tank, Ust closure plus 275 installation should be at least 35% less costly than a gas conversation. A dealer offered financing plan makes this coming affordable and most significantly, retains the oil account. project costs should be in the ,800-,000 range. With an interest free finance plan spread over 12 months, payments of 0-7 per month should be affordable.

In short, preclude your customer's from failing an private oil tank test by preventing it from happening in the first place. Eliminate the tank, take a proactive stance by replacing it and protect your buyer from what the laws of physics inevitably deed him.

By as a matter of fact disclosing the limitations of steel Ust's, then immediately offering an affordable solution, your buyer will believe you care as much for their financial welfare as your own. Liken it to an automobile recall due to a faulty component. It is good to embark on the recall than to defend a lawsuit. In our case, it is good to embark on a proactive clarification than to defend fuel oil's name as a polluter.

Questions & Answers

Question: What is the most proper tank closure method?

Answer: Regulatory Bulletins 88-3 and 91-4 mandate proper closure techniques. These techniques fall into two categories: in-place closure (aka abandonment) and unblemished removal. Ust Line #5* addresses the choice of extraction vs. In-place closure, recommending the latter as long as soils under the tank are tested. This Ust Line* introduces the "level of completion" concept, a big concern of homebuyers. This understanding is applied to each of the closure techniques specified in Bulletin 91-4.

Level of completion is a measure of job thoroughness in terms of both environmental issues and time to come liability. This criteria of thoroughness or completeness is becoming a major factor in determining the best coming for dealing with a particular private warehouse tank situation.

In terms of completeness, extraction is best, followed by open tank closure.

Removal vs. In-Place Closure. as a matter of fact the most proper job is done when the tank is completely removed. However, tank extraction is equipment-intensive, which makes it costlier than in-place closure. It is also a very invasive procedure, particularly if a complete deck or walkway is over or near the tank area. exterior restoration additional complicates the job and raises the cost.

With tank removal, cost must be weighed against level of completion. Is the homeowner planning to sell the home? The complete tank left in the ground can be a stumbling block. Gone are the days when one could simply state that the tank was taken care of... Today, the seller must provide certified evidence that the technique used to close the tank meets the intent of Bulletin 88-3 and, especially critical, that the tank never leaked. Tank extraction offers the top level of completion because the tank is now entirely eliminated.

In-place closure techniques fall into two categories: injection of concrete slurry or polyurethane foam down the fillpipe and pouring sand or gravel through a large opening. The old is completely non-disruptive, while the latter requires hand digging to the top of the tank, chance a 2' x 2' hole in the tank and as a matter of fact entering the vessel. The cost of each coming is almost the same. In terms of thoroughness, however, entering the tank is a far more unblemished coming because it allows the tank to be completely cleaned out of all sludge and residue and allows for leak inspection while inside.

*Ust Line is a monthly newsletter written by Mark Annis, President of Anco Environmental Services, Inc. For more information, please visit Anco's website at http://www.ancoenv.com.

share the Facebook Twitter Like Tweet. Can you share learn more here Failing an underground Oil Tank Test.